Home / Security / Advisories / NTAP-20231027-0002

NTAP-20231027-0002 — August 2023 Linux Kernel 6.5-rc5 Vulnerabilities in NetApp Products

Published 2023-10-27 · Updated 2025-05-29 · Status: Final · Exploitation: Public · Severity: MEDIUM 6.0 · ONTAP affected: No — other NetApp product

Official advisory: NTAP-20231027-0002 on security.netapp.com ↗. Affected versions, fixed releases, and workarounds live there — this page is a summary.

Product family: SolidFire / NetApp HCI  |  other NetApp product  |  highest CVSS: 6.0

CVEs in this advisory

What the CVE records say

CVE-2023-4273 — A flaw was found in the exFAT driver of the Linux kernel. The vulnerability exists in the implementation of the file name reconstruction function, which is responsible for reading file name entries from a directory index and merging file name parts belonging to one file into a single long file name. Since the file name characters are copied into a stack variable, a local privileged attacker could use this flaw to overflow the kernel stack.

CVE-2023-4128 — Rejected reason: ** REJECT ** DO NOT USE THIS CVE RECORD. ConsultIDs: CVE-2023-4206, CVE-2023-4207, CVE-2023-4208. Reason: This record is a duplicate of CVE-2023-4206, CVE-2023-4207, CVE-2023-4208. Notes: All CVE users should reference CVE-2023-4206, CVE-2023-4207, CVE-2023-4208 instead of this record. All references and descriptions in this record have been removed to prevent accidental usage.

CVE-2023-4194 — A flaw was found in the Linux kernel's TUN/TAP functionality. This issue could allow a local user to bypass network filters and gain unauthorized access to some resources. The original patches fixing CVE-2023-1076 are incorrect or incomplete. The problem is that the following upstream commits - a096ccca6e50 ("tun: tun_chr_open(): correctly initialize socket uid"), - 66b2c338adce ("tap: tap_open(): correctly initialize socket uid"), pass "inode->i_uid" to sock_init_data_uid() as the last parameter and that turns out to not be accurate.

Impact

Successful exploitation of these vulnerabilities could lead to disclosure of sensitive information, addition or modification of data, or Denial of Service (DoS).

Affected products

What to do

  1. Compare your installed product and version against the affected list above and the official advisory's affected-versions table.
  2. Apply the fixed release named in the official advisory, or the documented workaround if no fix ships yet.
  3. Limit management-plane exposure (BMC/management interfaces, web UIs, SNMP) until patched.
  4. Track follow-ups in the site CVE index and the security RSS feed.

Related reading

Browse all ONTAP CVEs → · Security hub