Home / Security / Advisories / NTAP-20260313-0007
NTAP-20260313-0007 — CVE-2025-68372 Linux Kernel Vulnerability in NetApp Products
Published 2026-03-13 · Updated 2026-10-28 · Status: Interim · Exploitation: Public · Severity: not scored · ONTAP affected: No — other NetApp product
Product family: Baseboard management controllers · Active IQ Unified Manager · NetApp Console / BlueXP · SolidFire / NetApp HCI | other NetApp product
CVEs in this advisory
What the CVE records say
CVE-2025-68372 — In the Linux kernel, the following vulnerability has been resolved: nbd: defer config put in recv_work There is one uaf issue in recv_work when running NBD_CLEAR_SOCK and NBD_CMD_RECONFIGURE: nbd_genl_connect // conf_ref=2 (connect and recv_work A) nbd_open // conf_ref=3 recv_work A done // conf_ref=2 NBD_CLEAR_SOCK // conf_ref=1 nbd_genl_reconfigure // conf_ref=2 (trigger recv_work B) close nbd // conf_ref=1 recv_work B config_put // conf_ref=0 atomic_dec(&config->recv_threads); -> UAF Or only running NBD_CLEAR_SOCK: nbd_genl_connect // conf_ref=2 nbd_open // conf_ref=3 NBD_CLEAR_SOCK // conf_ref=2 close nbd nbd_release config_put // conf_ref=1 recv_work config_put // conf_ref=0 atomic_dec(&config->recv_threads); -> UAF Commit 87aac3a80af5 ("nbd: call nbd_config_put() before notifying the waiter") moved nbd_config_put() to run before waking up the waiter in recv_work, in order to ensure that nbd_start_device_ioctl() would not be woken up while nbd->task_recv was still uncleared. However, in nbd_start_device_ioctl(), after being woken up it explicitly calls flush_workqueue() to make sure all current works are finished. Therefore, there is no need to move the config put ahead of the wakeup. Move nbd_config_put() to the end of recv_work, so that the reference is held for the whole lifetime of the worker thread. This makes sure the config cannot be freed while recv_work is still running, even if clear + reconfigure interleave. In addition, we don't need to worry about recv_work dropping the last nbd_put (which causes deadlock): path A (netlink with NBD_CFLAG_DESTROY_ON_DISCONNECT): connect // nbd_refs=1 (trigger recv_work) open nbd // nbd_refs=2 NBD_CLEAR_SOCK close nbd nbd_release nbd_disconnect_and_put flush_workqueue // recv_work done nbd_config_put nbd_put // nbd_refs=1 nbd_put // nbd_refs=0 queue_work path B (netlink without NBD_CFLAG_DESTROY_ON_DISCONNECT): connect // nbd_refs=2 (trigger recv_work) open nbd // nbd_refs=3 NBD_CLEAR_SOCK // conf_refs=2 close nbd nbd_release nbd_config_put // conf_refs=1 nbd_put // nbd_refs=2 recv_work done // conf_refs=0, nbd_refs=1 rmmod // nbd_refs=0 Depends-on: e2daec488c57 ("nbd: Fix hungtask when nbd_config_put")
Impact
Successful exploitation of this vulnerability could lead to disclosure of sensitive information, addition or modification of data, or Denial of Service (DoS).
Affected products
- AFF/ASA/FAS Baseboard Management Controller (BMC) - A1K/A90/A70/C80/FAS90/FAS70
- AFF/ASA/FAS Baseboard Management Controller (BMC) - A50/A30/A20/C60/C30/FAS50
- Active IQ Unified Manager for VMware vSphere
- NetApp Console Agent OVA
- NetApp HCI Baseboard Management Controller (BMC) - H610S
Official fixes
- AFF/ASA/FAS Baseboard Management Controller (BMC) - A1K/A90/A70/C80/FAS90/FAS70 — vendor fix ↗
- AFF/ASA/FAS Baseboard Management Controller (BMC) - A50/A30/A20/C60/C30/FAS50 — vendor fix ↗
References
What to do
- Compare your installed product and version against the affected list above and the official advisory's affected-versions table.
- Apply the fixed release named in the official advisory, or the documented workaround if no fix ships yet.
- Limit management-plane exposure (BMC/management interfaces, web UIs, SNMP) until patched.
- Track follow-ups in the site CVE index and the security RSS feed.
Related reading
- Site CVE index — every CVE we track, split by year
- Security hub — recent NetApp advisories and what changed
- Security hardening baseline — applies to NetApp management planes generally
- Every NetApp advisory published in 2026