Home / Security / Advisories / NTAP-20260313-0007

NTAP-20260313-0007 — CVE-2025-68372 Linux Kernel Vulnerability in NetApp Products

Published 2026-03-13 · Updated 2026-10-28 · Status: Interim · Exploitation: Public · Severity: not scored · ONTAP affected: No — other NetApp product

Official advisory: NTAP-20260313-0007 on security.netapp.com ↗. Affected versions, fixed releases, and workarounds live there — this page is a summary.

Product family: Baseboard management controllers · Active IQ Unified Manager · NetApp Console / BlueXP · SolidFire / NetApp HCI  |  other NetApp product

CVEs in this advisory

What the CVE records say

CVE-2025-68372 — In the Linux kernel, the following vulnerability has been resolved: nbd: defer config put in recv_work There is one uaf issue in recv_work when running NBD_CLEAR_SOCK and NBD_CMD_RECONFIGURE: nbd_genl_connect // conf_ref=2 (connect and recv_work A) nbd_open // conf_ref=3 recv_work A done // conf_ref=2 NBD_CLEAR_SOCK // conf_ref=1 nbd_genl_reconfigure // conf_ref=2 (trigger recv_work B) close nbd // conf_ref=1 recv_work B config_put // conf_ref=0 atomic_dec(&config->recv_threads); -> UAF Or only running NBD_CLEAR_SOCK: nbd_genl_connect // conf_ref=2 nbd_open // conf_ref=3 NBD_CLEAR_SOCK // conf_ref=2 close nbd nbd_release config_put // conf_ref=1 recv_work config_put // conf_ref=0 atomic_dec(&config->recv_threads); -> UAF Commit 87aac3a80af5 ("nbd: call nbd_config_put() before notifying the waiter") moved nbd_config_put() to run before waking up the waiter in recv_work, in order to ensure that nbd_start_device_ioctl() would not be woken up while nbd->task_recv was still uncleared. However, in nbd_start_device_ioctl(), after being woken up it explicitly calls flush_workqueue() to make sure all current works are finished. Therefore, there is no need to move the config put ahead of the wakeup. Move nbd_config_put() to the end of recv_work, so that the reference is held for the whole lifetime of the worker thread. This makes sure the config cannot be freed while recv_work is still running, even if clear + reconfigure interleave. In addition, we don't need to worry about recv_work dropping the last nbd_put (which causes deadlock): path A (netlink with NBD_CFLAG_DESTROY_ON_DISCONNECT): connect // nbd_refs=1 (trigger recv_work) open nbd // nbd_refs=2 NBD_CLEAR_SOCK close nbd nbd_release nbd_disconnect_and_put flush_workqueue // recv_work done nbd_config_put nbd_put // nbd_refs=1 nbd_put // nbd_refs=0 queue_work path B (netlink without NBD_CFLAG_DESTROY_ON_DISCONNECT): connect // nbd_refs=2 (trigger recv_work) open nbd // nbd_refs=3 NBD_CLEAR_SOCK // conf_refs=2 close nbd nbd_release nbd_config_put // conf_refs=1 nbd_put // nbd_refs=2 recv_work done // conf_refs=0, nbd_refs=1 rmmod // nbd_refs=0 Depends-on: e2daec488c57 ("nbd: Fix hungtask when nbd_config_put")

Impact

Successful exploitation of this vulnerability could lead to disclosure of sensitive information, addition or modification of data, or Denial of Service (DoS).

Affected products

Official fixes

References

What to do

  1. Compare your installed product and version against the affected list above and the official advisory's affected-versions table.
  2. Apply the fixed release named in the official advisory, or the documented workaround if no fix ships yet.
  3. Limit management-plane exposure (BMC/management interfaces, web UIs, SNMP) until patched.
  4. Track follow-ups in the site CVE index and the security RSS feed.

Related reading

Browse all ONTAP CVEs → · Security hub