Home / Security / Advisories / NTAP-20260327-0015
NTAP-20260327-0015 — CVE-2025-11234 QEMU Vulnerability in NetApp Products
Published 2026-03-27 · Updated 2026-09-25 · Status: Final · Exploitation: Public · Severity: HIGH 7.5 · ONTAP affected: No — other NetApp product
Product family: Baseboard management controllers · Other NetApp products · StorageGRID | other NetApp product | highest CVSS: 7.5
CVEs in this advisory
- CVE-2025-11234 — HIGH · CVSS 7.5 · site index
What the CVE records say
CVE-2025-11234 — A flaw was found in QEMU. If the QIOChannelWebsock object is freed while it is waiting to complete a handshake, a GSource is leaked. This can lead to the callback firing later on and triggering a use-after-free in the use of the channel. This can be abused by a malicious client with network access to the VNC WebSocket port to cause a denial of service during the WebSocket handshake prior to the VNC client authentication.
Impact
Successful exploitation of this vulnerability could lead to Denial of Service (DoS).
Affected products
- AFF/ASA/FAS Baseboard Management Controller (BMC) - A1K/A90/A70/C80/FAS90/FAS70
- FAS/AFF Baseboard Management Controller (BMC) - A800/C800
- FAS/AFF Baseboard Management Controller (BMC) - A900/9500
- FAS/AFF Baseboard Management Controller (BMC) - FAS2820
- NetApp Shift Toolkit
- StorageGRID (formerly StorageGRID Webscale)
References
What to do
- Compare your installed product and version against the affected list above and the official advisory's affected-versions table.
- Apply the fixed release named in the official advisory, or the documented workaround if no fix ships yet.
- Limit management-plane exposure (BMC/management interfaces, web UIs, SNMP) until patched.
- Track follow-ups in the site CVE index and the security RSS feed.
Related reading
- Site CVE index — every CVE we track, split by year
- Security hub — recent NetApp advisories and what changed
- Security hardening baseline — applies to NetApp management planes generally
- Every NetApp advisory published in 2026