Home / Security / Advisories / NTAP-20260417-0001
NTAP-20260417-0001 — CVE-2026-34197 Apache ActiveMQ Vulnerability in NetApp Products
Published 2026-04-17 · Updated 2026-08-21 · Status: Final · Exploitation: Public · Severity: HIGH 8.8 · ONTAP affected: No — other NetApp product
Product family: Active IQ Unified Manager · Other NetApp products · E-Series / SANtricity | other NetApp product | highest CVSS: 8.8
CVEs in this advisory
- CVE-2026-34197 — HIGH · CVSS 8.8 · site index
What the CVE records say
CVE-2026-34197 — Improper Input Validation, Improper Control of Generation of Code ('Code Injection') vulnerability in Apache ActiveMQ Broker, Apache ActiveMQ. Apache ActiveMQ Classic exposes the Jolokia JMX-HTTP bridge at /api/jolokia/ on the web console. The default Jolokia access policy permits exec operations on all ActiveMQ MBeans (org.apache.activemq:*), including BrokerService.addNetworkConnector(String) and BrokerService.addConnector(String). An authenticated attacker can invoke these operations with a crafted discovery URI that triggers the VM transport's brokerConfig parameter to load a remote Spring XML application context using ResourceXmlApplicationContext. Because Spring's ResourceXmlApplicationContext instantiates all singleton beans before the BrokerService validates the configuration, arbitrary code execution occurs on the broker's JVM through bean factory methods such as Runtime.exec(). This issue affects Apache ActiveMQ Broker: before 5.19.4, from 6.0.0 before 6.2.3; Apache ActiveMQ All: before 5.19.4, from 6.0.0 before 6.2.3; Apache ActiveMQ: before 5.19.4, from 6.0.0 before 6.2.3. Users are recommended to upgrade to version 5.19.4 or 6.2.3, which fixes the issue
Impact
Successful exploitation of this vulnerability could lead to disclosure of sensitive information, addition or modification of data, or Denial of Service (DoS).
Affected products
- Active IQ Unified Manager for Linux
- Active IQ Unified Manager for Microsoft Windows
- Active IQ Unified Manager for VMware vSphere
- Data Infrastructure Insights and Data Secure Storage Workload Security Agent
- E-Series SANtricity Unified Manager and Web Services Proxy
- Element Plug-in for vCenter Server
- SANtricity Storage Plugin for vCenter
References
What to do
- Compare your installed product and version against the affected list above and the official advisory's affected-versions table.
- Apply the fixed release named in the official advisory, or the documented workaround if no fix ships yet.
- Limit management-plane exposure (BMC/management interfaces, web UIs, SNMP) until patched.