Home / Security / Advisories / NTAP-20260807-0005
NTAP-20260807-0005 — CVE-2026-64531 Linux Kernel Vulnerability in NetApp Products
Published 2026-08-07 · Updated 2026-10-05 · Status: Interim · Exploitation: Public · Severity: HIGH 7.8 · ONTAP affected: No — other NetApp product
Product family: Brocade SAN firmware · NetApp Console / BlueXP · SolidFire / NetApp HCI · SnapCenter | other NetApp product | highest CVSS: 7.8
CVEs in this advisory
- CVE-2026-64531 — HIGH · CVSS 7.8 · site index
What the CVE records say
CVE-2026-64531 — In the Linux kernel, the following vulnerability has been resolved: net: openvswitch: reject oversized nested action attrs Open vSwitch stores generated flow actions as nlattrs, whose nla_len field is u16. Commit a1e64addf3ff ("net: openvswitch: remove misbehaving actions length check") allowed the total sw_flow_actions stream to grow beyond 64 KiB, which is valid, but also removed the last guard preventing a generated nested action attribute from exceeding U16_MAX. An oversized generated container can thus be closed with a truncated nla_len. A later dump or teardown then walks a structurally different stream than the one that was validated. In particular, an oversized nested CLONE/CT action may cause subsequent bytes in the generated stream to be interpreted as independent actions. Keep the larger total-action-stream behavior, but make nested action close reject generated containers that do not fit in nla_len, and return the error through all callers. For recursive SAMPLE, CLONE, DEC_TTL, and CHECK_PKT_LEN builders, trim resource-owning action-list tails in reverse construction order before discarding failed wrappers, so resources copied into the rejected tails are released before the wrappers are removed. Most failed outer wrappers are discarded by truncating actions_len after child resources have been released. CHECK_PKT_LEN also trims its parent after branch resources are gone. SET/TUNNEL close failures unwind their known tun_dst ownership directly, and SET_TO_MASKED has no external ownership and truncates on close failure.
Impact
Successful exploitation of this vulnerability could lead to disclosure of sensitive information, addition or modification of data, Denial of Service (DoS).
Affected products
- Brocade Fabric Operating System Firmware
- NetApp Console Agent OVA
- NetApp HCI Baseboard Management Controller (BMC) - H610S
- NetApp SolidFire & HCI Management Node
- NetApp SolidFire & HCI Storage Node (Element Software)
- SnapCenter Plug-in for VMware vSphere
References
What to do
- Compare your installed product and version against the affected list above and the official advisory's affected-versions table.
- Apply the fixed release named in the official advisory, or the documented workaround if no fix ships yet.
- Limit management-plane exposure (BMC/management interfaces, web UIs, SNMP) until patched.
- Track follow-ups in the site CVE index and the security RSS feed.