Home / Security / Advisories / NTAP-20260814-0005
NTAP-20260814-0005 — CVE-2026-64319 Linux Kernel Vulnerability in NetApp Products
Published 2026-08-14 · Updated 2026-10-05 · Status: Interim · Exploitation: Public · Severity: CRITICAL 9.1 · ONTAP affected: No — other NetApp product
Product family: Brocade SAN firmware · NetApp Console / BlueXP · SolidFire / NetApp HCI · SnapCenter | other NetApp product | highest CVSS: 9.1
CVEs in this advisory
- CVE-2026-64319 — CRITICAL · CVSS 9.1 · site index
What the CVE records say
CVE-2026-64319 — In the Linux kernel, the following vulnerability has been resolved: nvmet-auth: validate reply message payload bounds against transfer length nvmet_auth_reply() accesses the variable-length rval[] array using attacker-controlled hl (hash length) and dhvlen (DH value length) fields without verifying they fit within the allocated buffer of tl bytes. A malicious NVMe-oF initiator can craft a DHCHAP_REPLY message with a small transfer length but large hl/dhvlen values, causing out-of-bounds heap reads when the target processes the DH public key (rval + 2*hl) or performs the host response memcmp. With DH authentication configured, the OOB pointer is passed directly to sg_init_one() and read by crypto_kpp_compute_shared_secret(), reaching up to 526 bytes past the buffer. This is exploitable pre-authentication. Add bounds validation ensuring sizeof(*data) + 2*hl + dhvlen <= tl before any access to the variable-length fields. Discovered by Atuin - Automated Vulnerability Discovery Engine.
Impact
Successful exploitation of this vulnerability could lead to disclosure of sensitive information or Denial of Service (DoS).
Affected products
- Brocade Fabric Operating System Firmware
- NetApp Console Agent OVA
- NetApp HCI Baseboard Management Controller (BMC) - H610S
- SnapCenter Plug-in for VMware vSphere
References
What to do
- Compare your installed product and version against the affected list above and the official advisory's affected-versions table.
- Apply the fixed release named in the official advisory, or the documented workaround if no fix ships yet.
- Limit management-plane exposure (BMC/management interfaces, web UIs, SNMP) until patched.
- Track follow-ups in the site CVE index and the security RSS feed.
Related reading
- Site CVE index — every CVE we track, split by year
- Security hub — recent NetApp advisories and what changed
- Security hardening baseline — applies to NetApp management planes generally
- Every NetApp advisory published in 2026