Home / Security / Advisories / NTAP-20261104-0001
NTAP-20261104-0001 — CVE-2026-15176 NGINX Vulnerability in NetApp Products
Published 2026-11-04 · Updated 2026-11-04 · Status: Interim · Exploitation: Public · Severity: HIGH 8.1 · ONTAP affected: Yes
Product family: Active IQ Unified Manager · Brocade SAN firmware · SolidFire / NetApp HCI · NetApp Console / BlueXP · ONTAP · SnapCenter | ONTAP-relevant | highest CVSS: 8.1
CVEs in this advisory
- CVE-2026-15176 — HIGH · CVSS 8.1 · site index
What the CVE records say
CVE-2026-15176 — A vulnerability exists in NGINX Plus and NGINX Open Source when a location is configured that uses the alias directive together with rewrite and a set or return directive referencing the $request_filename variable. Alternatively, the same result could be achieved when the $request_filename variable is used in an access log format directive. An unauthenticated attacker along with conditions beyond their control can exploit this vulnerability by sending crafted HTTP requests. This may cause a heap buffer overflow in the NGINX worker process leading to a restart. Additionally, attackers can execute code on systems with Address Space Layout Randomization (ASLR) disabled or when the attacker can bypass ASLR. Impact: This vulnerability may allow remote attackers to cause a denial-of-service (DoS) on the NGINX system or to possibly trigger a code execution. There is no control plane exposure; this is a data plane issue only. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
Impact
Successful exploitation of this vulnerability could lead to disclosure of sensitive information, addition or modification of data, or Denial of Service (DoS).
Affected products
- Active IQ Unified Manager for Linux
- Active IQ Unified Manager for Microsoft Windows
- Active IQ Unified Manager for VMware vSphere
- Brocade SAN Navigator (SANnav)
- Management Services for Element Software and NetApp HCI
- NetApp Console Agent Container (static-file-server)
- NetApp SolidFire & HCI Management Node
- NetApp SolidFire & HCI Storage Node (Element Software)
- ONTAP Select Deploy administration utility
- SnapCenter Plug-in for VMware vSphere
References
What to do
- Check the affected products listed above against the official advisory's affected-versions table — that is where the exact ONTAP 9 release, ONTAP tool, or management product versions are named.
- If affected and a fixed release exists, plan the upgrade — see the ONTAP upgrade runbook.
- If exploitation is listed as "active", treat remediation as urgent and review exposure (management LIFs, ONTAP S3, SnapMirror endpoints).
- Harden in parallel: security hardening baseline and ransomware protection on ONTAP.
Related reading
- Common ONTAP problems (FAQ) — plain-language symptoms and fixes
- ONTAP security hardening — baseline lockdown guidance
- Ransomware protection on ONTAP — SnapLock, SnapMirror vaulting, Anomaly Detection
- ONTAP error messages index — EMS/WAFL/NFS/SnapMirror messages
- Every NetApp advisory published in 2026