Home / Security / Advisories / NTAP-20190719-0003
NTAP-20190719-0003 — May 2019 Linux Kernel Vulnerabilities in NetApp Products
Published 2019-07-19 · Updated 2020-06-12 · Status: Final · Exploitation: Public · Severity: HIGH 8.1 · ONTAP affected: Yes
Product family: Active IQ Unified Manager · Other NetApp products · SolidFire / NetApp HCI · ONTAP | ONTAP-relevant | highest CVSS: 8.1
CVEs in this advisory
- CVE-2018-20836 — HIGH · CVSS 8.1 · site index
- CVE-2019-11810 — HIGH · CVSS 7.5 · site index
- CVE-2019-11811 — HIGH · CVSS 7.0 · site index
- CVE-2019-11815 — HIGH · CVSS 8.1 · site index
What the CVE records say
CVE-2018-20836 — An issue was discovered in the Linux kernel before 4.20. There is a race condition in smp_task_timedout() and smp_task_done() in drivers/scsi/libsas/sas_expander.c, leading to a use-after-free.
CVE-2019-11810 — An issue was discovered in the Linux kernel before 5.0.7. A NULL pointer dereference can occur when megasas_create_frame_pool() fails in megasas_alloc_cmds() in drivers/scsi/megaraid/megaraid_sas_base.c. This causes a Denial of Service, related to a use-after-free.
CVE-2019-11811 — An issue was discovered in the Linux kernel before 5.0.4. There is a use-after-free upon attempted read access to /proc/ioports after the ipmi_si module is removed, related to drivers/char/ipmi/ipmi_si_intf.c, drivers/char/ipmi/ipmi_si_mem_io.c, and drivers/char/ipmi/ipmi_si_port_io.c.
CVE-2019-11815 — An issue was discovered in rds_tcp_kill_sock in net/rds/tcp.c in the Linux kernel before 5.0.8. There is a race condition leading to a use-after-free, related to net namespace cleanup.
Impact
Successful exploitation of these vulnerabilities could lead to disclosure of sensitive information, addition or modification of data, or Denial of Service (DoS).
Affected products
- Active IQ Unified Manager (formerly OnCommand Unified Manager) for VMware vSphere 9.5 and above
- Cluster Network Switch (NetApp CN1610)
- NetApp HCI Compute Node (Bootstrap OS)
- NetApp SolidFire & HCI Management Node
- NetApp SolidFire & HCI Storage Node (Element Software)
- NetApp VASA Provider for Clustered Data ONTAP 7.2 and above
- SnapProtect
- Storage Replication Adapter for Clustered Data ONTAP for VMware vSphere 7.2 and above
- Virtual Storage Console for VMware vSphere 7.2 and above
Official fixes
- Virtual Storage Console for VMware vSphere 7.2 and above — vendor fix ↗
- NetApp SolidFire & HCI Management Node — vendor fix ↗
- NetApp SolidFire & HCI Management Node — vendor fix ↗
- NetApp SolidFire & HCI Storage Node (Element Software) — vendor fix ↗
- NetApp SolidFire & HCI Storage Node (Element Software) — vendor fix ↗
- Active IQ Unified Manager (formerly OnCommand Unified Manager) for VMware vSphere 9.5 and above — vendor fix ↗
- Storage Replication Adapter for Clustered Data ONTAP for VMware vSphere 7.2 and above — vendor fix ↗
- NetApp HCI Compute Node (Bootstrap OS) — vendor fix ↗
References
What to do
- Check the affected products listed above against the official advisory's affected-versions table — that is where the exact ONTAP 9 release, ONTAP tool, or management product versions are named.
- If affected and a fixed release exists, plan the upgrade — see the ONTAP upgrade runbook.
- If exploitation is listed as "active", treat remediation as urgent and review exposure (management LIFs, ONTAP S3, SnapMirror endpoints).
- Harden in parallel: security hardening baseline and ransomware protection on ONTAP.