NTAP-20220707-0008 — CVE-2022-2068 OpenSSL Vulnerability in NetApp Products
Published 2022-07-07 · Updated 2026-03-11 · Status: Interim · Exploitation: Public · Severity: HIGH 7.3 · ONTAP affected: Yes
Product family: Brocade SAN firmware · Baseboard management controllers · Cloud Backup / AltaVault / SteelStore · SolidFire / NetApp HCI · E-Series / SANtricity · Other NetApp products · ONTAP · SnapManager / Snap utilities | ONTAP-relevant | highest CVSS: 7.3
CVEs in this advisory
- CVE-2022-2068 — HIGH · CVSS 7.3 · site index
What the CVE records say
CVE-2022-2068 — In addition to the c_rehash shell command injection identified in CVE-2022-1292, further circumstances where the c_rehash script does not properly sanitise shell metacharacters to prevent command injection were found by code review. When the CVE-2022-1292 was fixed it was not discovered that there are other places in the script where the file names of certificates being hashed were possibly passed to a command executed through the shell. This script is distributed by some operating systems in a manner where it is automatically executed. On such operating systems, an attacker could execute arbitrary commands with the privileges of the script. Use of the c_rehash script is considered obsolete and should be replaced by the OpenSSL rehash command line tool. Fixed in OpenSSL 3.0.4 (Affected 3.0.0,3.0.1,3.0.2,3.0.3). Fixed in OpenSSL 1.1.1p (Affected 1.1.1-1.1.1o). Fixed in OpenSSL 1.0.2zf (Affected 1.0.2-1.0.2ze).
Impact
Successful exploitation of this vulnerability could lead to disclosure of sensitive information, addition or modification of data, or Denial of Service (DoS).
Affected products
- Brocade SAN Navigator (SANnav)
- FAS/AFF Baseboard Management Controller (BMC) - 8300/8700/A400/C400
- NetApp Cloud Backup OST Plug-in (formerly AltaVault OST Plug-in)
- NetApp HCI Baseboard Management Controller (BMC) - H300S/H500S/H700S/H410S
- NetApp HCI Baseboard Management Controller (BMC) - H410C
- NetApp HCI Baseboard Management Controller (BMC) - H610C
- NetApp HCI Baseboard Management Controller (BMC) - H610S
- NetApp HCI Baseboard Management Controller (BMC) - H615C
- NetApp HCI Compute Node (Bootstrap OS)
- NetApp SANtricity SMI-S Provider
- NetApp SMI-S Provider
- NetApp SolidFire & HCI Management Node
Official fixes
- ONTAP Antivirus Connector — vendor fix ↗
- FAS/AFF Baseboard Management Controller (BMC) - 8300/8700/A400/C400 — vendor fix ↗
- NetApp SolidFire & HCI Management Node — vendor fix ↗
- NetApp SolidFire & HCI Storage Node (Element Software) — vendor fix ↗
- ONTAP Select Deploy administration utility — vendor fix ↗
References
What to do
- Check the affected products listed above against the official advisory's affected-versions table — that is where the exact ONTAP 9 release, ONTAP tool, or management product versions are named.
- If affected and a fixed release exists, plan the upgrade — see the ONTAP upgrade runbook.
- If exploitation is listed as "active", treat remediation as urgent and review exposure (management LIFs, ONTAP S3, SnapMirror endpoints).
- Harden in parallel: security hardening baseline and ransomware protection on ONTAP.
Related reading
- Common ONTAP problems (FAQ) — plain-language symptoms and fixes
- ONTAP security hardening — baseline lockdown guidance
- Ransomware protection on ONTAP — SnapLock, SnapMirror vaulting, Anomaly Detection
- ONTAP error messages index — EMS/WAFL/NFS/SnapMirror messages
- Every NetApp advisory published in 2022