Home / Security / Advisories / NTAP-20221209-0010

NTAP-20221209-0010 — October 2022 cURL/libcURL Vulnerabilities in NetApp Products

Published 2022-12-09 · Updated 2026-03-24 · Status: Interim · Exploitation: Public · Severity: HIGH 8.1 · ONTAP affected: Yes

Official advisory: NTAP-20221209-0010 on security.netapp.com ↗. Affected versions, fixed releases, and workarounds live there — this page is a summary.

Product family: Active IQ Unified Manager · Brocade SAN firmware · SolidFire / NetApp HCI · ONTAP  |  ONTAP-relevant  |  highest CVSS: 8.1

CVEs in this advisory

What the CVE records say

CVE-2022-42915 — curl before 7.86.0 has a double free. If curl is told to use an HTTP proxy for a transfer with a non-HTTP(S) URL, it sets up the connection to the remote server by issuing a CONNECT request to the proxy, and then tunnels the rest of the protocol through. An HTTP proxy might refuse this request (HTTP proxies often only allow outgoing connections to specific port numbers, like 443 for HTTPS) and instead return a non-200 status code to the client. Due to flaws in the error/cleanup handling, this could trigger a double free in curl if one of the following schemes were used in the URL for the transfer: dict, gopher, gophers, ldap, ldaps, rtmp, rtmps, or telnet. The earliest affected version is 7.77.0.

CVE-2022-42916 — In curl before 7.86.0, the HSTS check could be bypassed to trick it into staying with HTTP. Using its HSTS support, curl can be instructed to use HTTPS directly (instead of using an insecure cleartext HTTP step) even when HTTP is provided in the URL. This mechanism could be bypassed if the host name in the given URL uses IDN characters that get replaced with ASCII counterparts as part of the IDN conversion, e.g., using the character UTF-8 U+3002 (IDEOGRAPHIC FULL STOP) instead of the common ASCII full stop of U+002E (.). The earliest affected version is 7.77.0 2021-05-26.

Impact

Successful exploitation of these vulnerabilities could lead to disclosure of sensitive information, addition or modification of data, or Denial of Service (DoS). <br><br> ONTAP 9 (formerly Clustered Data ONTAP):<br> Affected only in 9.11.1. <br><br> Active IQ Unified Manager for VMware vSphere: <br> Affected by CVE-2022-42916 only in version 9.12.

Affected products

Official fixes

References

What to do

  1. Check the affected products listed above against the official advisory's affected-versions table — that is where the exact ONTAP 9 release, ONTAP tool, or management product versions are named.
  2. If affected and a fixed release exists, plan the upgrade — see the ONTAP upgrade runbook.
  3. If exploitation is listed as "active", treat remediation as urgent and review exposure (management LIFs, ONTAP S3, SnapMirror endpoints).
  4. Harden in parallel: security hardening baseline and ransomware protection on ONTAP.

Related reading