NTAP-20230110-0006 — December 2022 cURL/libcURL Vulnerabilities in NetApp Products
Published 2023-01-10 · Updated 2024-04-25 · Status: Interim · Exploitation: Public · Severity: CRITICAL 9.8 · ONTAP affected: Yes
Product family: Active IQ Unified Manager · SolidFire / NetApp HCI · ONTAP | ONTAP-relevant | highest CVSS: 9.8
CVEs in this advisory
- CVE-2022-32221 — CRITICAL · CVSS 9.8 · site index
- CVE-2022-35260 — MEDIUM · CVSS 6.5 · site index
What the CVE records say
CVE-2022-32221 — When doing HTTP(S) transfers, libcurl might erroneously use the read callback (`CURLOPT_READFUNCTION`) to ask for data to send, even when the `CURLOPT_POSTFIELDS` option has been set, if the same handle previously was used to issue a `PUT` request which used that callback. This flaw may surprise the application and cause it to misbehave and either send off the wrong data or use memory after free or similar in the subsequent `POST` request. The problem exists in the logic for a reused handle when it is changed from a PUT to a POST.
CVE-2022-35260 — curl can be told to parse a `.netrc` file for credentials. If that file endsin a line with 4095 consecutive non-white space letters and no newline, curlwould first read past the end of the stack-based buffer, and if the readworks, write a zero byte beyond its boundary.This will in most cases cause a segfault or similar, but circumstances might also cause different outcomes.If a malicious user can provide a custom netrc file to an application or otherwise affect its contents, this flaw could be used as denial-of-service.
Impact
Successful exploitation of these vulnerabilities could lead to disclosure of sensitive information, addition or modification of data, or Denial of Service (DoS). <br><br> Active IQ Unified Manager for VMware vSphere:<br> Affected by only CVE-2022-32221.
Affected products
- Active IQ Unified Manager for VMware vSphere
- NetApp HCI Baseboard Management Controller (BMC) - H300S/H500S/H700S/H410S
- NetApp HCI Compute Node (Bootstrap OS)
- NetApp SolidFire & HCI Management Node
- NetApp SolidFire & HCI Storage Node (Element Software)
- ONTAP 9 (formerly Clustered Data ONTAP)
Official fixes
- ONTAP 9 (formerly Clustered Data ONTAP) — vendor fix ↗
- ONTAP 9 (formerly Clustered Data ONTAP) — vendor fix ↗
- ONTAP 9 (formerly Clustered Data ONTAP) — vendor fix ↗
- ONTAP 9 (formerly Clustered Data ONTAP) — vendor fix ↗
- ONTAP 9 (formerly Clustered Data ONTAP) — vendor fix ↗
- ONTAP 9 (formerly Clustered Data ONTAP) — vendor fix ↗
- Active IQ Unified Manager for VMware vSphere — vendor fix ↗
What to do
- Check the affected products listed above against the official advisory's affected-versions table — that is where the exact ONTAP 9 release, ONTAP tool, or management product versions are named.
- If affected and a fixed release exists, plan the upgrade — see the ONTAP upgrade runbook.
- If exploitation is listed as "active", treat remediation as urgent and review exposure (management LIFs, ONTAP S3, SnapMirror endpoints).
- Harden in parallel: security hardening baseline and ransomware protection on ONTAP.